Assessment of the skin contamination dose coefficients for 252Cf radionuclide: Monte Carlo approach

dc.authorscopusidHesham M.H. Zakaly / 57196235532
dc.authorwosidHesham M.H. Zakaly / GFQ-4612-2022
dc.contributor.authorBoudaghi Malidarreh, Roya
dc.contributor.authorMostafa A.M.A.
dc.contributor.authorIssa, Shams A.M.
dc.contributor.authorZakaly, Hesham M.H
dc.date.accessioned2025-04-18T08:02:42Z
dc.date.available2025-04-18T08:02:42Z
dc.date.issued2024
dc.departmentİstinye Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Bilgisayar Mühendisliği Bölümü
dc.description.abstractHandling the 252Cf radionuclide source poses a potential hazard of skin surface contamination in case of an unexpected occurrence. Consequently, there is a growing need to establish precise dose conversion coefficients tailored to each type of emitted primary particle and various radionuclides. Nevertheless, the current body of literature does not provide specific data or methodologies for evaluating skin contamination dose and its associated coefficients, particularly with regard to the 252Cf source. Thus, this study aims to quantify the dose rate received by the skin and its associated coefficients after contamination scenario. Utilizing the established MCNPX environment, the Equivalent dose rate and Absorbed dose, along with Skin contamination dose coefficient (SCDC), have been calculated within the skin tissue. Two methodologies, specifically Watt Fission distribution and the Doppler Effect, are proposed to analyze particle spectra within skin phantom, enabling the calculation of Equivalent dose rate. In accordance with ICRP recommendations regarding the optimal depth for assessing skin doses, the designated scoring volume within the skin is located between depths of 50–100 μm. This volume is tasked with evaluating the dose. The SCDC results were entirely consistent with previously published data from MCNPX, with statistical uncertainties of less than 15%, demonstrating the efficacy of the methodologies employed in this study. This research presents an innovative method for generating data related to skin contamination doses. The novel outcomes in the current research facilitate the assessment of skin dose contamination for the targeted radionuclides and radiotherapy purposes due to staff oversight and radiobiological effects. © 2024 Elsevier Ltd
dc.description.sponsorshipDeanship of Graduate Studies and Scientific Research at Jouf University (DGSSR-2023-02-02464)
dc.identifier.citationMalidarreh, R. B., Mostafa, A. M. A., Issa, S. A., & Zakaly, H. M. (2024). Assessment of the skin contamination dose coefficients for 252Cf radionuclide: Monte Carlo approach. Radiation Measurements, 177, 107269.
dc.identifier.doi10.1016/j.radmeas.2024.107269
dc.identifier.issn13504487
dc.identifier.scopus2-s2.0-85201391591
dc.identifier.scopusqualityQ2
dc.identifier.urihttp://dx.doi.org/10.1016/j.radmeas.2024.107269
dc.identifier.urihttps://hdl.handle.net/20.500.12713/6513
dc.identifier.volume177
dc.identifier.wosWOS:001299311300001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWeb of Science
dc.institutionauthorZakaly, Hesham M.H.
dc.institutionauthoridHesham M.H. Zakaly / 0000-0002-7645-9964
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofRadiation Measurements
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject252Cf Radionuclide
dc.subjectEquivalent Dose Rate
dc.subjectMCNPX Monte-Carlo Simulation Environment
dc.subjectScoring volume
dc.subjectSkin contamination dose coefficient (SCDC)
dc.titleAssessment of the skin contamination dose coefficients for 252Cf radionuclide: Monte Carlo approach
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
1-s2.0-S1350448724002178-main.pdf
Boyut:
746.99 KB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: