Using the proportional dual integral strategy to improve the characteristics of the indirect field-oriented control of DFIG-based wind turbine systems

dc.authorscopusidİlhami Çolak / 6602990030
dc.authorwosidİlhami Çolak / KVO-7460-2024
dc.contributor.authorGasmi, Hamza
dc.contributor.authorBenbouhenni, Habib
dc.contributor.authorÇolak, İlhami
dc.contributor.authorTafticht, Tahar
dc.date.accessioned2025-04-18T07:38:26Z
dc.date.available2025-04-18T07:38:26Z
dc.date.issued2024
dc.departmentİstinye Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü
dc.description.abstractIn this work, a new indirect field-oriented command (IFOC) for wind systems based on a doubly-fed induction generator (DFIG) is designed to get better energy and stream quality. Also, overcoming the problems of IFOC. It is proposed to use proportional dual integral (PDI) controllers in order to replace traditional controllers and augment the robustness of the studied wind turbine system. The proposed IFOC-PDI is a modification of the IFOC, where the basic idea behind the designed technique is to combine a proportional-integral (PI) regulator with an integral term. This technique has been applied to the machine inverter, where the IFOC-PDI aims to calculate reference voltage values. The pulse width modulation (PWM) is used to translate voltage reference values ​​into pulses to run the machine inverter. The main objective of this article is to compare the competence of the IFOC-PDI to that of the IFOC-PI in different tests, including two different wind speed profiles and DFIG parameters variation. The major benefit of this command is a decrease in harmonic distortion of the currents, and active and reactive power (Ps and Qs) fluctuations. The results using MATLAB demonstrated that the IFOC-PDI improved the IFOC-PI in the minimization of stream harmonic distortion (6.63%, 10.42%, and 17.86%) and notable minimization of fluctuations in both Ps (32.08%, 46.24%, and 12.10%) and Qs (45.95%, 66.88%, and 14.49%). Also, the overshoot value of Ps was minimized compared to the IFOC-PI in all tests by ratios estimated at 57.79%, 12.41%, and 33.96%. The steady-state error of Ps was minimized compared to the IFOC-PI in all tests by ratios estimated at 29.43%, 85.88%, and 76.36%. The IFOC-PDI is also very resistant in the case of DFIG parameters variation. © 2024 The Author(s)
dc.identifier.citationGasmi, H., Benbouhenni, H., Colak, I., Tafticht, T., & Bizon, N. (2024). Using the proportional dual integral strategy to improve the characteristics of the indirect field-oriented control of DFIG-based wind turbine systems. e-Prime-Advances in Electrical Engineering, Electronics and Energy, 9, 100749.
dc.identifier.doi10.1016/j.prime.2024.100749
dc.identifier.endpage17
dc.identifier.issn27726711
dc.identifier.scopus2-s2.0-85202742214
dc.identifier.scopusqualityQ2
dc.identifier.startpage1
dc.identifier.urihttp://dx.doi.org/10.1016/j.prime.2024.100749
dc.identifier.urihttps://hdl.handle.net/20.500.12713/6468
dc.identifier.volume9
dc.indekslendigikaynakScopus
dc.institutionauthorÇolak, İlhami
dc.institutionauthoridİlhami Çolak / 0000-0002-6405-5938
dc.language.isoen
dc.publisherElsevier ltd
dc.relation.ispartofe-Prime - advances in electrical engineering, electronics and energy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDoubly-Fed Induction Generator
dc.subjectIndirect Field-Oriented Command
dc.subjectProportional Dual Integral Controller
dc.subjectPulse Width Modulation
dc.subjectWind System
dc.titleUsing the proportional dual integral strategy to improve the characteristics of the indirect field-oriented control of DFIG-based wind turbine systems
dc.typeArticle

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: