Investigating the Frequency of Stent Fracture and its Impact on in-Stent Restenosis in Patients Undergoing Carotid Artery Stenting

dc.authoridMehmet Altunova / 0000-0001-5351-5022
dc.authoridAhmet Arıf Yalcın / 0000-0002-9258-5389
dc.authoridFerhat Can Pıskın / 0000-0003-4092-1077
dc.authoridNedim Uzun / 0000-0001-9593-5869
dc.authoridAnıl Sahın / 0000-0003-1956-2348
dc.authoridYusuf Demir / 0000-0001-9167-493X
dc.authoridSezgin Atmaca / 0000-0002-0103-5905
dc.authoridGökhan Demirci / 0000-0003-2835-7530
dc.authoridMehmet Erturk / 0000-0002-2468-2793
dc.authorwosidAnıl Sahın / MGP-9567-2025
dc.contributor.authorAltunova, Mehmet
dc.contributor.authorYalcın, Ahmet Arıf
dc.contributor.authorIşık, Ayan
dc.contributor.authorPıskın, Ferhat Can
dc.contributor.authorUzun, Nedim
dc.contributor.authorSahın, Anıl
dc.contributor.authorDemir, Yusuf
dc.contributor.authorAtmaca, Sezgin
dc.contributor.authorDemirci, Gökhan
dc.contributor.authorErturk, Mehmet
dc.date.accessioned2025-04-18T09:17:10Z
dc.date.available2025-04-18T09:17:10Z
dc.date.issued23.10.2024
dc.departmentİstinye Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü
dc.description.abstractObjective: This single-center study aimed to assess the incidence and predictors of carotid artery Xact stent fractures (SF) and their impact on in-stent restenosis (ISR) during long-term follow-up. Methods: A cohort of 108 patients (97 males, median age 69.4±8 months) who underwent Xact stent placement for internal carotid artery stenosis between 2013 and 2021 and were diagnosed with SFs through fluoroscopy in 2022 were included. SFs were categorized as types I-V based on fracture characteristics. Follow-up included duplex ultrasound examinations to assess stent patency. Results: The average follow-up duration was 49.2±24.3 months, with ISR observed in 10 patients. Twenty-three SFs (21.3%) were identified: type I (5 patients), type II (7 patients), type III (3 patients), type IV (6 patients), and type V (2 patients). Calcification and stent length significantly predicted SFs (p<0.001; p<0.028). Conclusion: Calcification and stent length are associated with Xact SFs, but SFs do not impact ISR during long-term followup.
dc.identifier.citationALTUNOVA, M., YALCIN, A. A., IŞIK, A., PISKIN, F. C., UZUN, N., SAHIN, A., DEMIR, Y., ATMACA, S., DEMIRCI, G., ERTURK, M. (2024). Investigating the Frequency of Stent Fracture and its Impact on in-Stent Restenosis in Patients Undergoing Carotid Artery Stenting. Bezmiâlem Science , 12(3), 374 - 381. doi.org/10.14235/bas.galenos.2024.68736
dc.identifier.doi10.14235/bas.galenos.2024.68736
dc.identifier.endpage381
dc.identifier.issue3
dc.identifier.startpage374
dc.identifier.trdizinid1273742
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1273742/investigating-the-frequency-of-stent-fracture-and-its-impact-on-in-stent-restenosis-in-patients-undergoing-carotid-artery-stenting
dc.identifier.urihttps://hdl.handle.net/20.500.12713/6745
dc.identifier.volume12
dc.identifier.wosWOS:001395966800013
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorSahın, Anıl
dc.institutionauthoridAnıl Sahın / 0000-0003-1956-2348
dc.language.isoen
dc.publisherGalenos Yayınevi
dc.relation.ispartofBezmiâlem Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectInternal carotid artery
dc.subjectXact stents
dc.subjectstent fracture
dc.subjectin- stent restenosis
dc.titleInvestigating the Frequency of Stent Fracture and its Impact on in-Stent Restenosis in Patients Undergoing Carotid Artery Stenting
dc.title.alternativeKarotis Arterine Stent Uygulanan Hastalarda Stent Kırığı Sıklığının ve Stent İçi Restenoz Üzerine Etkisinin Araştırılması
dc.typeArticle

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: