    Assessment of extremity dose for medical staff involved in positron emission tomography/computed tomography imaging: Retrospective study
    (Lippincott Williams & Wilkins, 2023) Erdemir, Rabiye Uslu; Abuzaid, Mohamed Mahmoud; Cavli, Baris; Tekin, Huseyin Ozan; Elshami, Wiam
    There has been an increase in positron emission tomography (PET)/computed tomography (CT) imaging procedures, and medical workers involved in PET/CT are at increased risk of occupational exposure. Data on extremity dose exposure are limited globally. The current study aimed to evaluate the occupational radiation dose for extremities for medical workers (nurses, radiographers/radiologic technologists, and nuclear medicine physicians) working in PET/CT scanners at 5 large hospitals in Turkey. Optically stimulated luminescence (OSL) and Thermoluminescent dosimeter (TLD) ring dosimeters were used to measure equivalent dose values. Hospitals 1, 2, and 5 used OSL, and 3 and 4 used TLD. A total of 502 readings were obtained from 55 workers. In millisievert (mSv), the average annual effective dose for all workers was 14.5 +/- 17.7 (0.2-157.2). A radiography technologist received a maximum dose of 157.21. Nurses received the highest average annual effective dose (15.2 +/- 19.46) (0.32-65.58), followed by radiography technologists (14.7 +/- 18.03) (0.4-157.2), and nuclear medicine physicians demonstrated the least dose (8.6 +/- 10.5) (1.2-24.4). The results show that the extremity dose is well below the annual dose limit of 500 mSv. However, there is a wide variation in dose among the workers, underlining a need for careful assessment of working conditions to ensure safe practices for all workers.
  • Küçük Resim Yok
    Öğe
    A comparative analysis of shielding effectiveness in glass and concrete containers
    (De Gruyter Poland Sp Z O O, 2024) ALMmisned, Ghada; Sen Baykal, Duygu; Elshami, Wiam; Susoy, Gulfem; Kilic, Gokhan; Tekin, Huseyin Ozan
    Nuclear waste control and related equipment play a vital role in safeguarding human health and the environment from the potential dangers of radioactive waste. This study addresses the critical challenge of enhancing the shielding effectiveness of container materials for nuclear waste management, with a focus on comparing the attenuation properties of glass and concrete composites. Our analysis revealed that the copper oxide-reinforced borosilicate glass container demonstrated a significant transmission factor (TF) value decrease by approximately 15% compared to steel-magnetite concrete at 1.3325 MeV, with a standard deviation of +/- 1.5%, indicating its lower protective characteristics. Nonetheless, it exhibited a 10% higher TF reduction compared to the cement-bitumen mix at the same energy level, with a precision error of +/- 1.2%. In addition, the half-value layer for this glass was determined to be 2.5 cm for 1.3325 MeV gamma rays, showing moderate shielding capacity. The study demonstrates that optimizing the oxide content in the borosilicate glass matrix significantly enhances its shielding effectiveness. This advancement in nuclear waste management materials is justified by our comprehensive evaluation, highlighting the potential of optimized glass materials to outperform traditional concrete in certain scenarios, thus contributing to the development of more effective nuclear waste containment solutions.
  • Küçük Resim Yok
    Öğe
    Investigation of Radiochromic Film Use for Source Position Verification through a LINAC On-Board Imager (OBI)
    (Mdpi, 2023) Karacam, Songul Cavdar; Tuncman, Duygu; ALMisned, Ghada; Ene, Antoaneta; Tekin, Huseyin Ozan
    Background and Objectives: Quality assurance is an integral part of brachytherapy. Traditionally, radiographic films have been used for source position verification, however, in many clinics, computerized tomography simulators have replaced conventional simulators, and computerized radiography systems have replaced radiographic film processing units. With these advances, the problem of controlling source position verification without traditional radiographic films and conventional simulators has appeared. Materials and Methods: In this study, we investigated an alternative method for source position verification for brachytherapy applications. Source positions were evaluated using Gafchromic (TM) RTQA2 and EBT3 film and visually compared to exposed RTQA radiochromic film when using a Nucletron Oldelft Simulix HP conventional simulator and a Gammamed 12-i brachytherapy device for performance evaluation. Gafchromic film autoradiography was performed with a linear accelerator (LINAC) on-board imager (OBI). Radiochromic films are very suitable for evaluation by visual inspection with a LINAC OBI. Results: The results showed that this type of low-cost, easy-to-find material can be used for verification purposes under clinical conditions. Conclusions: It can be concluded that source-position quality assurance may be performed through a LINAC OBI device.
  • Küçük Resim Yok
    Öğe
    Structural, physical, and radiation absorption properties of a significant nuclear power plant component: A comparison between REX-734 and 316L SS austenitic stainless steels
    (De Gruyter Poland Sp Z O O, 2023) Say, Yakup; Guler, Omer; Kavaz, Esra; ALMisned, Ghada; Ene, Antoaneta; Tekin, Huseyin Ozan
    Austenitic stainless steels (SSs) are commonly used as in-core and surrounding structural materials in today's industrial BWR and PWR systems. Such adaptable steels have also been the primary materials studied and used in several advanced nuclear reactor technologies, such as fast breeding and magnetic fusion reactors. In this study, some critical material properties, such as structural, physical, and radiation-shielding properties of REX-734 and 316L SS, were experimentally evaluated and compared to those of a number of other alloys. In addition to homogeneous element distribution, both alloys exhibit strong crystal orientation. The REX-734 alloy has a tensile strength of 1,259 MPa, whereas the 316L SS alloy has a tensile strength of 495 MPa. Moreover, nitrogen in the REX-734 alloy formed ultra-hard nitrides with Cr, Nb, and Si and precipitated into the structure and increased the strength. According to our findings, the mass attenuation coefficient values of the 316L SS sample were slightly higher than those of the REX-734 sample at all energies. It can be concluded that the REX-734 sample, with its exceptional strength qualities and excellent radiation attenuation capabilities, may be a viable nuclear power plant material for future investigations.

| İstinye Üniversitesi | Kütüphane | Açık Bilim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İstinye Üniversitesi, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim