Arşiv logosu
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Guven, Mehmet Esad" seçeneğine göre listele

Listeleniyor 1 - 4 / 4
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Dimensional Stability of Additively Manufactured Diagnostic Maxillary Casts Fabricated with Different Model Resins
    (QUINTESSENCE PUBLISHING CO INC, 22.08.2024) Donmez, Mustafa Borga; Wepfer, Alena Bruna; Guven, Mehmet Esad; Cakmak, Gulce; Schimmel, Martin; Yilmaz, Burak
    Purpose: To evaluate the effect of model resin type and time interval on the dimensional stability of additively manufactured diagnostic casts. Materials and Methods: Ten irreversible hydrocolloid impressions and 10 impressions from an intraoral scanner were made from a reference maxillary stone cast, which was also digitized with a laboratory scanner. Conventional impressions were poured in type III stone (SC), while digital impressions were used to additively manufacture casts with a nanographene-reinforced model resin (GP) or a model resin (DM). All casts were digitized with the same laboratory scanner 1 day (T0), 1 week (T1), 2 weeks ( T2), 3 weeks ( T3), and 4 weeks ( T4) after fabrication. Cast scans were superimposed over the reference cast scan to evaluate dimensional stability. Data were analyzed with Bonferroni-corrected repeated measures ANOVA (alpha =.05). Results: The interaction between the main factors (material type and time interval) affected anterior teeth deviations, while the individual main factors affected anterior teeth and entire- cast deviations (P =.008). Within anterior teeth, DM had the lowest deviations at T3, and GP mostly had lower values at T2 and lower deviations at T3 than at T0 (P =.041). SC had the highest pooled anterior teeth deviations, and GP had the highest pooled entire cast deviations (P <.001). T3 had lower pooled anterior teeth deviations than at T0, T1, and T4, and higher pooled entire cast deviations than T1 were demonstrated (P =.027). Conclusions: The trueness of nanographene-reinforced casts was either similar to or higher than that of other casts. Dimensional changes were acceptable during the course of 1 month.
  • Küçük Resim Yok
    Öğe
    Effect of internal connection type and screw channel angle on the screw stability of anterior implant-supported zirconia crowns
    (Wiley, 2023) Cakmak, Guelce; Guven, Mehmet Esad; Donmez, Mustafa Borga; Kahveci, Cigdem; Schimmel, Martin; Abou-Ayash, Samir; Yilmaz, Burak
    ObjectivesTo investigate the effect of implant-abutment connection and screw channel angle on screw stability by comparing a newly introduced and an established connection, before and after cyclic loading.Materials and MethodsImplants (N = 44) with Torcfit (TF) or Crossfit (CF) connection were divided to be restored with a straight (CFS and TFS) or an angled screw access channel (CFA and TFA) titanium-base abutment (n = 11). CFA and TFA received screw-retained crowns, whereas CFS and TFS received hybrid zirconia abutments and cement-retained crowns. The initial torque value (ITV) of each complex (ITVI) and removal torque value (RTV) after 24 h (RTVI) were measured. Screws were replaced with new ones, ITVs were recorded again (ITVF), and crowns were cyclically loaded (2.4 million cycles, 98 N) to measure RTVs again (RTVF). Percentage torque loss was calculated. Data were analyzed (a = 0.05).ResultsITVs were similar among groups (p = .089). CF led to higher RTVs (p = .002), while CFS had higher RTVI than CFA (p = .023). After 24 h, CFS had lower percentage torque loss than TF, while CFA had lower percentage torque loss than TFA (p = .011). After cyclic loading, CF led to lower percentage torque (p < .001).ConclusionThe implant-abutment connection affected the removal torque values. However, no screw loosening occurred during cyclic loading, which indicated a stable connection for all groups. Screw access channel angle did not affect screw stability after cyclic loading.
  • Küçük Resim Yok
    Öğe
    Evaluation of Dimensional Stability and Occlusal Wear of Additively and Subtractively Manufactured Resin-Based Crowns after Thermomechanical Aging
    (Mdpi, 2023) Guven, Mehmet Esad; Cakmak, Gulce; Donmez, Mustafa Borga; Yilmaz, Burak
    The knowledge on the surface deviations and wear of recently introduced additively or subtractively manufactured materials indicated for definitive prosthesis is limited. The aim of this present study was to evaluate the external surface and mesiodistal width deviation and the occlusal surface wear of one additively manufactured composite resin (MS) and three subtractively manufactured resins (nanographene-reinforced polymethylmethacrylate (GR), conventional polymethylmethacrylate (PMMA), and reinforced composite resin (BC)) after thermomechanical aging. Molar-shaped crowns were fabricated in the tested materials and digitized with an intraoral scanner (CEREC Primescan; Dentsply Sirona, Bensheim, Germany). Each crown was subjected to thermomechanical aging and rescanned with the same scanner. A three-dimensional analysis software (Geomagic Control X v.2022.1; 3D Systems, Rock Hill, SC, USA) was used to calculate the deviations on the external surface, mesiodistal width, and wear on the occlusal surfaces of the tested crowns. Data were analyzed using one-way ANOVA and Tukey's tests (alpha = 0.05). MS had higher external surface deviations than PMMA and GR (p <= 0.038) and higher mesiodistal width deviations than PMMA and BC (p = 0.004). BC and GR had higher volume loss than PMMA (p <= 0.002). The additively manufactured composite resin was more prone to deviations, while reinforced composite resin had lower wear resistance than most of the tested materials.
  • Küçük Resim Yok
    Öğe
    Trueness and precision of combined healing abutment scan body system scans at different sites of maxilla after multiple repositioning of the scan body
    (Elsevier Sci Ltd, 2023) Donmez, Mustafa Borga; Guven, Mehmet Esad; Yilmaz, Deniz; Abou-Ayash, Samir; Cakmak, Gulce; Yilmaz, Burak
    Objectives: To evaluate the accuracy of the scans of the combined healing abutment-scan body (CHA-SB) system located at different sites of the maxilla when SBs are replaced in between each scan.Methods: Three SBs were seated into HAs located at the central incisor, first premolar, and first molar sites of a maxillary model inside a phantom head, and the model was scanned extraorally (CEREC Primescan SW 5.2). This procedure was repeated with new SBs until a total of 10 scans were performed. Standard tessellation language files of CHA-SBs at each implant location were isolated, transferred into analysis software (Geomagic Control X), and superimposed over the proprietary library files to analyze surface (root mean square), linear, and angular deviations. Trueness and precision were evaluated with one-way analysis of variance and Tukey tests. The correlation between surface and angular deviations was analyzed with Pearson's correlation (alpha=0.05).Results: Molar implant scans had the highest surface and angular deviations (P <=.006), while central incisor implant scans had higher precision (surface deviations) than premolar implant scans (P=.041). Premolar implant scans had higher accuracy than central incisor implant scans on the y-axis (P <=.029). Central incisor implant scans had the highest accuracy on the z-axis (P <=.018). A strong positive correlation was observed between surface and angular deviations (r = 0.864, P<.001).Conclusion: Central incisor implant scans mostly had high accuracy and molar implant scans mostly had lower trueness. SBs were mostly positioned apically; however, the effect of SB replacement can be considered small as measured deviations were similar to those in previous studies and the precision of scans was high.Clinical Significance: Repositioning of scan bodies into healing abutments would be expected to result in similar single crown positioning regardless of the location of the implant, considering high scan precision with the healing abutment-scan body system. The duration of the chairside adjustments of crowns in the posterior maxilla may be longer than those in the anterior region.

| İstinye Üniversitesi | Kütüphane | Açık Bilim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İstinye Üniversitesi, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim